The rule depends on the build date
Victoria has three bands. Find the year your house was built, or the year of its last major renovation or extension.
| House built or largely renovated | Minimum the law requires |
|---|---|
| Before 1 August 1997 | Smoke alarms that meet AS 3786. Battery-powered alarms are allowed |
| 1 August 1997 to 30 April 2014 | Alarms wired to 240 volt mains power, with a back-up battery |
| From 1 May 2014 | Alarms wired to 240 volt mains power, with a back-up battery, and interconnected where there is more than one |
Every smoke alarm in every band must meet the Australian Standard, AS 3786.
Where the alarms have to go
The legal minimum is the same for every house:
- on or near the ceiling of every storey
- between each bedroom area and the rest of the house.
In a two-storey house with no bedrooms upstairs, an alarm goes near the top of the stairs. With bedrooms upstairs, one goes near the stairs on the ground floor as well.
That is the minimum. CFA and Fire Rescue Victoria recommend an alarm in every bedroom and every living area.
Renovations and extensions move you up a band
The 1997 and 2014 dates apply to houses that were built, largely renovated or extended after them. A 1970s house that was largely renovated or extended after 1 May 2014 comes under the 2014 rule.
On a job with a building permit, the building surveyor marks the number and position of the alarms on the plans. If you are extending and adding bedrooms, ask the surveyor early. The new alarms can pull the existing ones into the interconnected system.
When you replace an alarm, the replacement must meet at least the standard the house was built to. A hard-wired alarm is replaced with a hard-wired alarm.
Interconnected alarms
Interconnected alarms are linked. When one detects smoke, all of them sound. A fire in the garage sets off the alarm outside the bedrooms.
There are two ways to do it:
- Hard-wired. A cable links the alarms through the roof space. An electrician installs it.
- Wireless. The alarms talk to each other by radio. Battery versions with a sealed ten-year battery can be fitted without an electrician.
Fire Rescue Victoria’s advice for any house is that it is best to replace old alarms with hard-wired, interconnected ones. In a house built before 1997 that is a choice, not a requirement.
Every alarm is replaced at ten years
All smoke alarms are replaced after ten years. That includes hard-wired alarms. The expiry or manufacture date is on the unit, usually under the battery cover or on the back.
Between replacements, the fire services’ routine is:
- test every alarm each month by holding the test button
- vacuum or dust around each alarm once a year
- replace nine-volt batteries once a year.
A single chirp every 30 seconds or so means the battery is low. If it keeps chirping with a new battery, check the date. An alarm at the end of its life does the same thing.
Who can install them
A hard-wired smoke alarm is connected to the 240 volt wiring. It must be installed or replaced by a licensed electrician. You should receive a Certificate of Electrical Safety for the work.
Anyone can change a back-up battery. Anyone can fit a battery-only alarm.
Changing battery alarms to hard-wired ones means running cable to each alarm position and linking the alarms. In most houses that is done through the roof space. We look at the existing alarms and the roof access first, then give a fixed price.
Rental properties
The rental rules sit on top of the build-date rules. Since 25 November 2025 they apply to every rental agreement, whenever it started.
The rental provider must make sure every smoke alarm:
- is correctly installed and working
- has a battery fitted
- is tested at least once every 12 months, the way the manufacturer says to test it.
The rental provider must also give the renter written information, at or before the start of the agreement, on how each alarm works, how to test it, and the renter’s duty to report a fault.
A smoke alarm that is not working is an urgent repair. The rental provider must arrange the repair or replacement straight away. Work on a mains-powered alarm has to be done by a suitably qualified person.
The renter must tell the rental provider when an alarm is faulty, and must not remove, disable or interfere with one.
Rentals also need an electrical safety check every two years. We test the smoke alarms on the same visit. Our guide to what changed for rental safety checks on 13 October 2026 covers that rule.
What we install
We fit hard-wired, interconnected photoelectric alarms as standard, in owner-occupied homes and rentals across Frankston and the south-east. The install date goes on every unit. The interconnection is tested across the whole house before we leave.
Tell us the number of bedrooms, the number of levels and the layout. We will tell you how many alarms the house needs before we come out. Details are on the smoke alarm installation page.