Hard-wired or battery smoke alarms: the Victorian rules by the year your house was built

Which smoke alarms a Victorian house needs depends on when it was built or renovated. The 1997 and 2014 rules, the rental rules and who can install them.

  • Licensed & insured
  • Local Frankston Team

Short answer

A house built after 1 August 1997 must have smoke alarms wired to 240 volt mains power with a back-up battery. A house built or largely renovated after 1 May 2014 must also have them interconnected, so they all sound together. A house built before 1 August 1997 may have battery alarms.

Every alarm, of any type, is replaced after ten years. A hard-wired alarm must be installed by a licensed electrician.

On this page
  1. The rule depends on the build date
  2. Where the alarms have to go
  3. Renovations and extensions move you up a band
  4. Interconnected alarms
  5. Every alarm is replaced at ten years
  6. Who can install them
  7. Rental properties
  8. What we install

The rule depends on the build date

Victoria has three bands. Find the year your house was built, or the year of its last major renovation or extension.

House built or largely renovated Minimum the law requires
Before 1 August 1997 Smoke alarms that meet AS 3786. Battery-powered alarms are allowed
1 August 1997 to 30 April 2014 Alarms wired to 240 volt mains power, with a back-up battery
From 1 May 2014 Alarms wired to 240 volt mains power, with a back-up battery, and interconnected where there is more than one

Every smoke alarm in every band must meet the Australian Standard, AS 3786.

Where the alarms have to go

The legal minimum is the same for every house:

  • on or near the ceiling of every storey
  • between each bedroom area and the rest of the house.

In a two-storey house with no bedrooms upstairs, an alarm goes near the top of the stairs. With bedrooms upstairs, one goes near the stairs on the ground floor as well.

That is the minimum. CFA and Fire Rescue Victoria recommend an alarm in every bedroom and every living area.

Renovations and extensions move you up a band

The 1997 and 2014 dates apply to houses that were built, largely renovated or extended after them. A 1970s house that was largely renovated or extended after 1 May 2014 comes under the 2014 rule.

On a job with a building permit, the building surveyor marks the number and position of the alarms on the plans. If you are extending and adding bedrooms, ask the surveyor early. The new alarms can pull the existing ones into the interconnected system.

When you replace an alarm, the replacement must meet at least the standard the house was built to. A hard-wired alarm is replaced with a hard-wired alarm.

Interconnected alarms

Interconnected alarms are linked. When one detects smoke, all of them sound. A fire in the garage sets off the alarm outside the bedrooms.

There are two ways to do it:

  • Hard-wired. A cable links the alarms through the roof space. An electrician installs it.
  • Wireless. The alarms talk to each other by radio. Battery versions with a sealed ten-year battery can be fitted without an electrician.

Fire Rescue Victoria’s advice for any house is that it is best to replace old alarms with hard-wired, interconnected ones. In a house built before 1997 that is a choice, not a requirement.

Every alarm is replaced at ten years

All smoke alarms are replaced after ten years. That includes hard-wired alarms. The expiry or manufacture date is on the unit, usually under the battery cover or on the back.

Between replacements, the fire services’ routine is:

  • test every alarm each month by holding the test button
  • vacuum or dust around each alarm once a year
  • replace nine-volt batteries once a year.

A single chirp every 30 seconds or so means the battery is low. If it keeps chirping with a new battery, check the date. An alarm at the end of its life does the same thing.

Who can install them

A hard-wired smoke alarm is connected to the 240 volt wiring. It must be installed or replaced by a licensed electrician. You should receive a Certificate of Electrical Safety for the work.

Anyone can change a back-up battery. Anyone can fit a battery-only alarm.

Changing battery alarms to hard-wired ones means running cable to each alarm position and linking the alarms. In most houses that is done through the roof space. We look at the existing alarms and the roof access first, then give a fixed price.

Rental properties

The rental rules sit on top of the build-date rules. Since 25 November 2025 they apply to every rental agreement, whenever it started.

The rental provider must make sure every smoke alarm:

  • is correctly installed and working
  • has a battery fitted
  • is tested at least once every 12 months, the way the manufacturer says to test it.

The rental provider must also give the renter written information, at or before the start of the agreement, on how each alarm works, how to test it, and the renter’s duty to report a fault.

A smoke alarm that is not working is an urgent repair. The rental provider must arrange the repair or replacement straight away. Work on a mains-powered alarm has to be done by a suitably qualified person.

The renter must tell the rental provider when an alarm is faulty, and must not remove, disable or interfere with one.

Rentals also need an electrical safety check every two years. We test the smoke alarms on the same visit. Our guide to what changed for rental safety checks on 13 October 2026 covers that rule.

What we install

We fit hard-wired, interconnected photoelectric alarms as standard, in owner-occupied homes and rentals across Frankston and the south-east. The install date goes on every unit. The interconnection is tested across the whole house before we leave.

Tell us the number of bedrooms, the number of levels and the layout. We will tell you how many alarms the house needs before we come out. Details are on the smoke alarm installation page.

Sources

Read on 22 November 2026. Rules change. Check the linked page for the current wording.

Common questions

Do smoke alarms have to be hard-wired in Victoria?
In a house built after 1 August 1997, yes. They must be on 240 volt mains power with a back-up battery. A house built before that date may have battery-powered alarms.
Do smoke alarms have to be interconnected in Victoria?
In a house built, largely renovated or extended after 1 May 2014, yes, where the house needs more than one alarm. In an older house it is not required. The fire services recommend it for every house.
Can I replace a hard-wired smoke alarm myself?
No. A hard-wired alarm is connected to 240 volts, and it must be installed or replaced by a licensed electrician. Anyone can change the back-up battery. Battery-only alarms, including the wireless interconnected kind, can be fitted without an electrician.
My hard-wired alarm still works. Do I really replace it at ten years?
Yes. CFA and Fire Rescue Victoria both say every alarm is replaced after ten years, including hard-wired ones. The date is printed on the unit. The sensor ages whether or not the test button still makes a noise.
Who checks smoke alarms in a rental?
The rental provider. Since 25 November 2025 every Victorian rental must have its smoke alarms tested at least once every 12 months. The renter must report an alarm that is not working and must not remove or disable one.

What we can do

  • Smoke alarm installation

    Hard-wired, interconnected photoelectric alarms. Fixed price, tested across the house, certificate on completion.

    Smoke alarm installation
  • Electrical safety check

    The two-yearly rental check, with the smoke alarms tested while we are there.

    Electrical safety check

More articles from the blog

Tell us about the alarms

Pick any
Your details

Talk to a licensed electrician

Based in Frankston North. Fixed price before we start. After-hours call-outs for urgent faults.