Streamline electrician inspecting an outdoor meter box on a brick wall
Rules and rentals

Electrical safety checks for Victorian rentals: what changed on 13 October 2026

Since 13 October 2026 every Victorian rental needs an electrical safety check every two years, older leases included. What it covers and who can do it.

  • Licensed & insured
  • Local Frankston Team

Short answer

Since 13 October 2026 every rental property in Victoria must have an electrical safety check every two years, done by a licensed or registered electrician. Before that date the rule covered only agreements that started on or after 29 March 2021.

If you rent out a property on an older lease and it has not been checked in the last two years, it is now due.

On this page
  1. What changed
  2. Who is caught now
  3. What the check covers
  4. Who can do it
  5. The record you must hold
  6. The switchboard standard is a separate rule
  7. The check is not the repair
  8. Smoke alarms and gas
  9. If you are the renter
  10. Booking a check

What changed

Two-yearly electrical safety checks have been compulsory since March 2021, but only for rental agreements that started on or after 29 March 2021. A property with a long-standing renter on an older agreement was outside the rule.

On 13 October 2026 that gap closed. Consumer Affairs Victoria’s wording is that rental providers must arrange gas and electrical safety checks every two years “in all rental properties”.

The same change added three things:

  • A renter on an older agreement can ask, in writing, for the date of the last electrical safety check.
  • If no check was done in the two years before a renter moves in, the rental provider must arrange one as soon as possible.
  • Rental providers and agents must keep records showing the property met the minimum rental standards before it was advertised or occupied, and hand them to Consumer Affairs Victoria if asked.

Who is caught now

  • Properties let on an agreement that started before 29 March 2021.
  • Properties where that older agreement rolled into a month-to-month arrangement.
  • Properties that have had the same renter for years and have never had a check.

If the property was already on the two-year cycle, nothing changes. The next check falls due two years after the last one.

What the check covers

The Residential Tenancies Act now defines the check. It is a check of all electrical installations, fixtures and fittings, carried out in accordance with section 4 of AS/NZS 3019, the standard for periodic assessment of electrical installations.

In practice that means inspection and testing of:

  • the mains coming into the property and the switchboard
  • safety switches, circuit breakers and fuses
  • power points and light fittings
  • the wiring that can be reached
  • fixed appliances the owner supplies, such as the oven, the hot water unit and air conditioners
  • solar systems and vehicle chargers, where the property has them.

The tests are polarity, earth continuity, and safety switch tests by push button and by trip time. Energy Safe Victoria’s check report also has a section for smoke alarms.

Who can do it

A licensed electrician or a registered electrician. Our checks are done and signed by A-grade licensed electricians.

You can check any electrician’s licence on the Energy Safe Victoria website.

The record you must hold

The electrician gives you a record of the check. It must show:

  • the electrician’s name and licence or registration number
  • the date of the check
  • the results, including any repairs needed and what was done about them
  • a report prepared in accordance with section 2 of AS/NZS 3019.

Then three duties follow:

  1. Keep the record until the next check creates a new one.
  2. Give the renter a copy within seven days of a written request.
  3. Before a new agreement is signed, tell the renter the date of the last check and any recommendations still outstanding.

The switchboard standard is a separate rule

The check often finds the board is the problem. Since 29 March 2023 the rental minimum standard has required every power outlet and lighting circuit to be connected to a circuit breaker and a safety switch at the switchboard.

Two points from Consumer Affairs Victoria matter for older properties:

  • On a board that already has circuit breakers, an electrician can add safety switch protection to the power and lighting circuits. Circuits for the oven, the hot water and the air conditioner do not have to be changed.
  • On an old fuse board that may not be possible. The whole board may need replacing, and then every circuit on the new board gets protection.

The minimum standards have their own rules about which agreements they apply to. They apply to agreements that started, or became month to month, on or after 29 March 2021, and a property must meet them before it is advertised. So an older lease can be caught by the safety check rule and not yet by the switchboard standard. The check report will still say what the board lacks, and the standard applies the next time the property is let.

Our switchboard upgrades page covers what replacing a board involves.

The check is not the repair

The check is an inspection and a report. Anything it finds is a separate job.

  • Anything dangerous is made safe on the day.
  • Each fault is listed in the report with a quote to fix it.
  • Repairs come with a Certificate of Electrical Safety.

Energy Safe Victoria says plainly that a Certificate of Electrical Safety is not the right form for recording the check itself. If someone hands you only a certificate, you do not have the record the law asks for.

Smoke alarms and gas

Smoke alarms have their own rule. Since 25 November 2025 every rental must have its smoke alarms tested at least once every 12 months. We test them on the same visit as the electrical check. The build-date rules are in our guide to hard-wired and battery smoke alarms.

The gas safety check is also two-yearly. A licensed gasfitter does it, and it is only needed where there are gas appliances or fittings. We do not do gas.

If you are the renter

  • Ask your rental provider or agent, in writing, for the date of the last electrical safety check.
  • Ask in writing for a copy of the record. They have seven days to provide it.
  • If no check has been done, the two-yearly check is a duty under the Act. You can give a breach of duty notice. If nothing happens, you can apply to VCAT.
  • A dangerous electrical fault is an urgent repair. Report it straight away. Do not wait for the next check.

Booking a check

We do rental safety checks across Frankston, Seaford, Carrum Downs, Langwarrin, Mount Eliza and the Mornington Peninsula. The check is a fixed price. The report is written for your agent’s file. Repairs are quoted separately and you decide.

Property managers can send us a list of properties and we will quote them together. Details are on the electrical safety check page.

Sources

Read on 22 November 2026. Rules change. Check the linked page for the current wording.

Common questions

Does a lease that started before March 2021 need an electrical safety check now?
Yes. From 13 October 2026 the two-yearly electrical safety check applies to all rental properties in Victoria, whenever the agreement started.
Is there a deadline for a property that has never been checked?
The law does not give one, and it gives no grace period either. The duty is a check every two years. We read that as: a property with no check in the last two years is due now.
Is the check the same as a Certificate of Electrical Safety?
No. A Certificate of Electrical Safety is issued for electrical work that has been carried out. The safety check produces a report on the installation as it stands. If repairs follow, the repairs come with a certificate.
What is the fine for not doing the check?
Consumer Affairs Victoria lists no set fine for missing the two-yearly check. It is a duty under the Residential Tenancies Act. A renter can give a breach of duty notice and take it to VCAT, which can order the check done and order compensation. Failing to disclose the date of the last check before a new agreement is different. That carries a penalty of up to 60 penalty units for an individual, $12,546 in 2026-27.
Do you do the gas safety check as well?
No. The gas check is a separate two-yearly check done by a licensed gasfitter. It is only needed where the property has gas appliances or fittings.
Can you do the check with the renter living there?
Yes. We need access to the switchboard, every room and the roof space if there is a manhole. The agent usually arranges the time with the renter.

What we can do

  • Electrical safety check

    The two-yearly rental check to AS/NZS 3019. Written report for your agent, fixed price, repairs quoted separately.

    Electrical safety check
  • Switchboard upgrades

    Ceramic fuses and boards without safety switches brought up to the rental standard.

    Switchboard upgrades
  • Smoke alarm installation

    Alarms past ten years replaced, tested and dated.

    Smoke alarm installation

More articles from the blog

Book a rental safety check

Pick any
Your details

Talk to a licensed electrician

Based in Frankston North. Fixed price before we start. After-hours call-outs for urgent faults.